SERVOMEX 1800 OXGYEN ANALYZER. O2 ANALYZER 15PPM Bilge Alarm / Recording / Alarm / Oil discharge / Ship monitoring system.
SERVOMEX
1800 OXGYEN ANALYZER
We can supply all 15PPM Bilge Alarm / Recording / Alarm / Oil discharge / Ship monitoring system.
We
maintain a large inventory of Instrumentation & Automation related items
and their Spare Parts, as well as entire units are provided immediately and at
highly competitive price.
For more details feel free to contact / email us info@dutchmarinesupply.com
The Servomex 1800
analyzer is a stable, accurate and highly specific oxygen analyzer for safe
areas.
- Designed for safe areas OXYGN analysis
- Low maintenance and re-calibration requirements
- Range of alarm output to aid integration with other system
- Easy to set up and operate
- Special versions for solvent bearing samples
- Special high flow rate cell option
Specification:
Gases Measured
O₂
PERFORMANCE
Technology:
Paramagnetic transducer
Range:
0 – 100% O₂
Intrinsic Error
(accuracy):
<0.2% of reading or 0.05% O₂
¹
Linearity:
<0.05% O₂ ²
Repeatability:
<0.1% of reading or 0.05% O₂
¹
Response time(T₉₀)
4 to 8 seconds ³
Zero drift / week:
<0.05% O₂
Span drift / week:
<1% of reading or 0.05% O₂ ¹
SIGNAL OUTPUTS
Analog:
One 4-20 mA, isolated & one 0-1 dc, non-isolated. Range
selectable from 0 – 2.5, 5, 10, 25 and 100% O₂
Alarm:
Concentration:
Sample flow fall:
Two dry contact SPDT relays rated 250Vac/3A or 28Vdc
(non inductive) maximum and 5V/10mA ac/dc minimum
One dry contact SPDT realys rated 250Vac/3A or 28Vdc
(non inductive) maximum and 5V/10mA ac/dc minimum
PHYSICAL
Dimension:
(w × D ×
H)
17.6" × 9" × 9.25" / 448mm ×
229mm ×235mm
Weight:
57 Ibs / 26 kg
Hazardous area
sclassification:
Non-Hazardous Areas only
Ingress Protection:
IP 66 / NEMA 4X
Mounting:
Wall or Panel
Specification:
Gases Measured
O₂
PERFORMANCE
Technology:
Paramagnetic transducer
Range:
0 – 100% O₂
Intrinsic Error
(accuracy):
<0.2% of reading or 0.05% O₂
¹
Linearity:
<0.05% O₂ ²
Repeatability:
<0.1% of reading or 0.05% O₂
¹
Response time(T₉₀)
4 to 8 seconds ³
Zero drift / week:
<0.05% O₂
Span drift / week:
<1% of reading or 0.05% O₂ ¹
SIGNAL OUTPUTS
Analog:
One 4-20 mA, isolated & one 0-1 dc, non-isolated. Range
selectable from 0 – 2.5, 5, 10, 25 and 100% O₂
Alarm:
Concentration:
Sample flow fall:
Two dry contact SPDT relays rated 250Vac/3A or 28Vdc
(non inductive) maximum and 5V/10mA ac/dc minimum
One dry contact SPDT realys rated 250Vac/3A or 28Vdc
(non inductive) maximum and 5V/10mA ac/dc minimum
PHYSICAL
Dimension:
(w × D ×
H)
17.6" × 9" × 9.25" / 448mm ×
229mm ×235mm
Weight:
57 Ibs / 26 kg
Hazardous area
sclassification:
Non-Hazardous Areas only
Ingress Protection:
IP 66 / NEMA 4X
Mounting:
Wall or Panel